- status_text: decode the 24-bit "status" field into human-readable flag names (e.g. "Cell Temp Low, Low Voltage") instead of raw hex, using the bit table pulled from com.lithionics.bms's array/advanced resource (dumped with aapt -- the app's own StatusCodeTable class references stale/wrong resource IDs and can't be trusted for this). Applied to "status" only; last_fault_code is a lifetime latch that accumulates many bits over time and isn't meaningfully summarized the same way. - Fixed the info sensors (total_consumed, firmware_version, serial_number, etc.) showing "Unavailable" in HA a minute after connecting: they were getting the same expire_after as the periodic telemetry sensors, but the $info line the come from is only sent once per BLE connection, so HA's expire timer always fired. These are retained-topic diagnostics meant to hold their last value indefinitely; expire_after now only applies to the periodic SENSORS group. - STUCK_DISCOVERY_THRESHOLD 3 -> 1: restart bluetooth.service after the first failed scan instead of waiting for three, cutting reconnect time roughly in third. Still rate-limited via BLUETOOTH_RESTART_COOLDOWN_S. Also removed the per-line "RAW ..." debug print (was flooding the journal). All three changes verified live on host wan via journalctl/mosquitto_sub.
377 lines
15 KiB
Python
Executable File
377 lines
15 KiB
Python
Executable File
#!/usr/bin/python3 -u
|
|
# Publish Lithionics Li3 BMS battery telemetry to Home Assistant via MQTT
|
|
# discovery. Protocol reverse-engineered from the com.lithionics.bms Android
|
|
# app (BLEMaster / MainBmsCsParameters): classic HM-10 BLE-UART (service
|
|
# ffe0, characteristic ffe1, notify+write, no pairing). On connect we send
|
|
# "$traceon" then "$info"; the device then streams CRLF-terminated CSV
|
|
# telemetry lines forever.
|
|
#
|
|
# BLE connect failures are retried internally (MQTT session stays up across
|
|
# them) rather than exiting, because bluetoothd on this Pi's onboard adapter
|
|
# occasionally wedges its discovery state after a run of failed connection
|
|
# attempts (Discovering stays "yes" forever, and every subsequent connect
|
|
# fails with le-connection-abort-by-local) — observed happening from our own
|
|
# repeated scan/connect cycling, not anything external. We restart
|
|
# bluetooth.service ourselves as soon as a scan fails to clear that, rate-
|
|
# limited (BLUETOOTH_RESTART_COOLDOWN_S) so we don't do it so often it
|
|
# disrupts the other BLE gear on this hub (motion sensors, IR remote, etc.
|
|
# also served by bluetoothd here).
|
|
#
|
|
# Only exits (letting systemd Restart=always give us a fresh process) on
|
|
# MQTT-level failure, which shouldn't happen in normal operation.
|
|
|
|
import asyncio
|
|
import json
|
|
import subprocess
|
|
import sys
|
|
import time
|
|
|
|
import paho.mqtt.client as mqtt
|
|
from bleak import BleakClient, BleakScanner
|
|
|
|
BLE_RETRY_DELAY_S = 8
|
|
STUCK_DISCOVERY_THRESHOLD = 1 # consecutive scan failures before we intervene
|
|
BLUETOOTH_RESTART_COOLDOWN_S = 300 # don't restart bluetooth.service more than this often
|
|
|
|
config_path = sys.argv[1] if len(sys.argv) > 1 else "/etc/van-li3/config.json"
|
|
with open(config_path) as f:
|
|
cfg = json.load(f)
|
|
|
|
ADDR = cfg["ble_address"]
|
|
FFE1 = "0000ffe1-0000-1000-8000-00805f9b34fb"
|
|
|
|
broker = cfg["broker"]
|
|
mqtt_port = cfg.get("port", 1883)
|
|
mq_user = cfg["username"]
|
|
mq_pw = cfg["password"]
|
|
client_id = cfg.get("client_id", "van-li3-battery")
|
|
|
|
device_id = cfg.get("device_id", "li3_battery")
|
|
device_name = cfg.get("device_name", "Li3 Battery")
|
|
|
|
discovery_prefix = cfg.get("discovery_prefix", "homeassistant")
|
|
state_topic = cfg.get("state_topic", f"van/{device_id}/state")
|
|
publish_interval_s = cfg.get("publish_interval_s", 15)
|
|
|
|
SENSORS = [
|
|
# (key, name, unit, device_class, display_precision) -- precision None means
|
|
# a non-numeric value (hex code, version string, serial number): published
|
|
# as-is with no unit, no rounding, no state_class.
|
|
("voltage", "Pack Voltage", "V", "voltage", 2),
|
|
("cell1_voltage", "Cell 1 Voltage", "V", "voltage", 2),
|
|
("cell2_voltage", "Cell 2 Voltage", "V", "voltage", 2),
|
|
("cell3_voltage", "Cell 3 Voltage", "V", "voltage", 2),
|
|
("cell4_voltage", "Cell 4 Voltage", "V", "voltage", 2),
|
|
("current", "Current", "A", "current", 2),
|
|
("soc", "State of Charge", "%", "battery", 0),
|
|
("bms_temperature", "BMS Temperature", "°F", "temperature", 1),
|
|
("battery_temperature", "Battery Temperature", "°F", "temperature", 1),
|
|
# From "&" trace lines (streamed continuously once $traceon is sent) --
|
|
# CAN-charger bus fields. This battery has no CAN charger wired up, so
|
|
# can_charger_voltage/current are observed as a fixed sentinel and
|
|
# can_charger_status/can_status never change; published anyway since
|
|
# they're genuine decoded fields.
|
|
("remaining_capacity", "Remaining Capacity", "Ah", None, 0),
|
|
("remaining_time", "Remaining Time", "min", "duration", 0),
|
|
("can_charger_voltage", "CAN Charger Voltage", "V", "voltage", 1),
|
|
("can_charger_current", "CAN Charger Current", "A", "current", 1),
|
|
("can_charger_status", "CAN Charger Status", None, None, None),
|
|
("can_status", "CAN Status", None, None, None),
|
|
]
|
|
|
|
# From the "$" info line, sent once by the device right after $info and never
|
|
# repeated -- published separately (own retained state topic) rather than
|
|
# merged into the periodic telemetry above.
|
|
INFO_SENSORS = [
|
|
("total_consumed", "Lifetime Consumed", "Ah", None, 0),
|
|
("last_fault_code", "Last Fault Code", None, None, None),
|
|
("highest_recorded_temp", "Highest Recorded Temperature", "°F", "temperature", 0),
|
|
("lowest_recorded_temp", "Lowest Recorded Temperature", "°F", "temperature", 0),
|
|
("firmware_version", "Firmware Version", None, None, None),
|
|
("aging_factor_temp", "Aging Factor (Temp)", None, None, 0),
|
|
("aging_factor_soc", "Aging Factor (SOC)", None, None, 0),
|
|
("serial_number", "Serial Number", None, None, None),
|
|
]
|
|
|
|
info_topic = cfg.get("info_topic", f"van/{device_id}/info")
|
|
|
|
# The "status" field (main Cs telemetry line, and identically-coded but
|
|
# cumulative/latched "last_fault_code" from $info) is a 24-bit flag mask.
|
|
# Bit meanings pulled from the app's own "advanced" string-array resource
|
|
# (com.lithionics.bms base.apk, array/advanced -- dumped with aapt since the
|
|
# app's Kotlin StatusCodeTable class references stale/wrong resource IDs and
|
|
# can't be trusted). Index 0 = bit 23 (MSB) down to index 23 = bit 0 (LSB);
|
|
# blank entries are unused bits. Applied to "status" only -- last_fault_code
|
|
# is a lifetime latch (many bits accumulate over time) and isn't meaningfully
|
|
# summarized the same way.
|
|
STATUS_FLAGS = [
|
|
"", "BMS Temp High", "Overcurrent State", "Charge OFF", "Aux Input State",
|
|
"Cell Temp Low", "Cell Temp High", "AGSR State", "Temp Sensor Fault",
|
|
"CAN Charger Fault", "CAN Charger Present", "AC Power Present",
|
|
"Contactor Flutter", "Pre-Charge Fault", "Contactor Fault",
|
|
"Contactor State", "Power Off State", "Battery Protection", "Low Voltage",
|
|
"Reserve Range", "OptoLoop Open", "NeverDie Reserve", "Charge Detected",
|
|
"High Voltage",
|
|
]
|
|
|
|
|
|
def decode_status(hex_code):
|
|
try:
|
|
value = int(hex_code, 16)
|
|
except (ValueError, TypeError):
|
|
return hex_code
|
|
active = [
|
|
label for i, label in enumerate(STATUS_FLAGS)
|
|
if label and (value >> (23 - i)) & 1
|
|
]
|
|
return ", ".join(active) if active else "OK"
|
|
|
|
|
|
def parse_line(line):
|
|
"""Cs-series main telemetry line (no prefix character)."""
|
|
parts = line.split(",")
|
|
try:
|
|
f0 = int(parts[0])
|
|
except ValueError:
|
|
return None
|
|
if not (101 <= f0 <= 9999):
|
|
return None # not a Cs-series main telemetry line
|
|
try:
|
|
return {
|
|
"voltage": round(f0 * 0.01, 2),
|
|
"cell1": round(int(parts[1]) * 0.01, 2),
|
|
"cell2": round(int(parts[2]) * 0.01, 2),
|
|
"cell3": round(int(parts[3]) * 0.01, 2),
|
|
"cell4": round(int(parts[4]) * 0.01, 2),
|
|
"bms_temp_f": int(parts[5]),
|
|
"batt_temp_f": int(parts[6]),
|
|
"current_a": int(parts[7]),
|
|
"soc_pct": int(parts[8]),
|
|
"status": parts[9] if len(parts) > 9 else "?",
|
|
}
|
|
except (ValueError, IndexError):
|
|
return None
|
|
|
|
|
|
def parse_trace_line(line):
|
|
"""'&' trace line: &,batteryId,remaining,remainingTime,canChargerVoltage,
|
|
canChargerCurrent,canChargerStatus,canStatus"""
|
|
parts = line.split(",")
|
|
try:
|
|
return {
|
|
"remaining_capacity": int(parts[2]),
|
|
"remaining_time": int(parts[3]),
|
|
"can_charger_voltage": round(int(parts[4]) * 0.1, 1),
|
|
"can_charger_current": round(int(parts[5]) * 0.1, 1),
|
|
"can_charger_status": parts[6],
|
|
"can_status": parts[7],
|
|
}
|
|
except (ValueError, IndexError):
|
|
return None
|
|
|
|
|
|
def parse_info_line(line):
|
|
"""'$' info line (response to $info): $,totalConsumed,lastFaultCode,
|
|
highestRecordedTemp,lowestRecordedTemp,firmwareVersion,agingFactorTemp,
|
|
agingFactorSoc,serialNumber"""
|
|
parts = line.split(",")
|
|
try:
|
|
return {
|
|
"total_consumed": int(parts[1]),
|
|
"last_fault_code": parts[2],
|
|
"highest_recorded_temp": int(parts[3]),
|
|
"lowest_recorded_temp": int(parts[4]),
|
|
"firmware_version": parts[5],
|
|
"aging_factor_temp": int(parts[6]),
|
|
"aging_factor_soc": int(parts[7]),
|
|
"serial_number": parts[8],
|
|
}
|
|
except (ValueError, IndexError):
|
|
return None
|
|
|
|
|
|
def _sensor_config(key, name, unit, device_class, precision, topic_state, device_info, expire_after=None):
|
|
numeric = precision is not None
|
|
payload = {
|
|
"name": name,
|
|
"unique_id": f"{device_id}_{key}",
|
|
"state_topic": topic_state,
|
|
"unit_of_measurement": unit,
|
|
"device_class": device_class,
|
|
"value_template": (
|
|
f"{{{{ value_json.{key} | round({precision}) }}}}"
|
|
if numeric
|
|
else f"{{{{ value_json.{key} }}}}"
|
|
),
|
|
"device": device_info,
|
|
}
|
|
if expire_after is not None:
|
|
payload["expire_after"] = expire_after
|
|
if numeric:
|
|
payload["suggested_display_precision"] = precision
|
|
payload["state_class"] = "measurement"
|
|
return payload
|
|
|
|
|
|
def publish_discovery(mqc):
|
|
device_info = {
|
|
"identifiers": [device_id],
|
|
"name": device_name,
|
|
"manufacturer": "Lithionics",
|
|
"model": "Li3 BMS",
|
|
}
|
|
for key, name, unit, device_class, precision in SENSORS:
|
|
topic = f"{discovery_prefix}/sensor/{device_id}/{key}/config"
|
|
payload = _sensor_config(
|
|
key, name, unit, device_class, precision, state_topic, device_info,
|
|
expire_after=publish_interval_s * 4,
|
|
)
|
|
mqc.publish(topic, json.dumps(payload), retain=True)
|
|
|
|
status_topic = f"{discovery_prefix}/sensor/{device_id}/status/config"
|
|
status_payload = {
|
|
"name": "Status",
|
|
"unique_id": f"{device_id}_status",
|
|
"state_topic": state_topic,
|
|
"value_template": "{{ value_json.status_text }}",
|
|
"device": device_info,
|
|
"expire_after": publish_interval_s * 4,
|
|
}
|
|
mqc.publish(status_topic, json.dumps(status_payload), retain=True)
|
|
|
|
for key, name, unit, device_class, precision in INFO_SENSORS:
|
|
topic = f"{discovery_prefix}/sensor/{device_id}/{key}/config"
|
|
payload = _sensor_config(key, name, unit, device_class, precision, info_topic, device_info)
|
|
payload["entity_category"] = "diagnostic"
|
|
mqc.publish(topic, json.dumps(payload), retain=True)
|
|
|
|
|
|
def publish_info(mqc, info):
|
|
"""Publish the once-per-connection '$info' fields as their own retained
|
|
message, separate from the periodic telemetry state."""
|
|
mqc.publish(info_topic, json.dumps(info), retain=True)
|
|
print("published info:", info)
|
|
|
|
|
|
def build_state_payload(cs_reading, trace_fields):
|
|
# A non-zero status means the rest of the Cs line's fields are unreliable
|
|
# (observed 2026-08-18: status '69' alongside e.g. current=341, soc=340,
|
|
# cell4_voltage=34013.63) — publish only the status in that case. Trace
|
|
# ("&" line) fields come from a separate message and are published
|
|
# regardless.
|
|
status = cs_reading["status"]
|
|
if status != "000000":
|
|
payload = {"status": status}
|
|
else:
|
|
payload = {
|
|
"voltage": cs_reading["voltage"],
|
|
"cell1_voltage": cs_reading["cell1"],
|
|
"cell2_voltage": cs_reading["cell2"],
|
|
"cell3_voltage": cs_reading["cell3"],
|
|
"cell4_voltage": cs_reading["cell4"],
|
|
"current": cs_reading["current_a"],
|
|
"soc": cs_reading["soc_pct"],
|
|
"bms_temperature": cs_reading["bms_temp_f"],
|
|
"battery_temperature": cs_reading["batt_temp_f"],
|
|
"status": status,
|
|
}
|
|
payload["status_text"] = decode_status(status)
|
|
payload.update(trace_fields)
|
|
return payload
|
|
|
|
|
|
def restart_bluetooth_service():
|
|
print("scan failed; restarting bluetooth.service")
|
|
subprocess.run(["systemctl", "restart", "bluetooth.service"], check=False)
|
|
time.sleep(3)
|
|
|
|
|
|
async def find_device():
|
|
"""Scan/connect retry loop. Never gives up; self-heals a wedged
|
|
bluetoothd discovery state along the way. Returns a found device."""
|
|
consecutive_failures = 0
|
|
last_bluetooth_restart = 0.0
|
|
while True:
|
|
print("scanning for device...")
|
|
dev = await BleakScanner.find_device_by_address(ADDR, timeout=20)
|
|
if dev:
|
|
return dev
|
|
consecutive_failures += 1
|
|
print(f"device not found in scan (attempt {consecutive_failures})")
|
|
if consecutive_failures >= STUCK_DISCOVERY_THRESHOLD:
|
|
now = time.time()
|
|
if (now - last_bluetooth_restart) >= BLUETOOTH_RESTART_COOLDOWN_S:
|
|
restart_bluetooth_service()
|
|
last_bluetooth_restart = now
|
|
consecutive_failures = 0
|
|
await asyncio.sleep(BLE_RETRY_DELAY_S)
|
|
|
|
|
|
async def stream_from_device(dev, mqc):
|
|
"""Connect to `dev` and publish readings until it disconnects."""
|
|
buf = ""
|
|
last_publish = 0.0
|
|
latest_cs = {}
|
|
latest_trace = {}
|
|
info_published = False
|
|
|
|
def notify_handler(_sender, data):
|
|
nonlocal buf, info_published
|
|
buf += data.decode("utf-8", errors="replace")
|
|
while "\r\n" in buf:
|
|
line, buf = buf.split("\r\n", 1)
|
|
line = line.strip()
|
|
if not line:
|
|
continue
|
|
if line.startswith("&"):
|
|
trace = parse_trace_line(line)
|
|
if trace:
|
|
latest_trace.update(trace)
|
|
elif line.startswith("$"):
|
|
if not info_published:
|
|
info = parse_info_line(line)
|
|
if info:
|
|
publish_info(mqc, info)
|
|
info_published = True
|
|
else:
|
|
reading = parse_line(line)
|
|
if reading:
|
|
latest_cs.update(reading)
|
|
|
|
async with BleakClient(dev, timeout=15) as client:
|
|
print("connected")
|
|
await client.start_notify(FFE1, notify_handler)
|
|
await client.write_gatt_char(FFE1, b"$traceon\r\n", response=False)
|
|
await asyncio.sleep(2)
|
|
await client.write_gatt_char(FFE1, b"$info\r\n", response=False)
|
|
|
|
while client.is_connected:
|
|
await asyncio.sleep(1)
|
|
now = time.time()
|
|
if latest_cs and (now - last_publish) >= publish_interval_s:
|
|
payload = build_state_payload(latest_cs, latest_trace)
|
|
mqc.publish(state_topic, json.dumps(payload))
|
|
# print("published:", payload)
|
|
last_publish = now
|
|
print("disconnected")
|
|
|
|
|
|
async def main():
|
|
mqc = mqtt.Client(mqtt.CallbackAPIVersion.VERSION2, client_id=client_id)
|
|
mqc.username_pw_set(mq_user, mq_pw)
|
|
mqc.connect(broker, mqtt_port, keepalive=60)
|
|
mqc.loop_start()
|
|
publish_discovery(mqc)
|
|
|
|
while True:
|
|
dev = await find_device()
|
|
try:
|
|
await stream_from_device(dev, mqc)
|
|
except Exception as e:
|
|
print("connection error:", e)
|
|
await asyncio.sleep(BLE_RETRY_DELAY_S)
|
|
|
|
|
|
if __name__ == "__main__":
|
|